Accelerate to discover

Back to filter

Related topics

Advancing Alzheimer's disease rsearch with IncuCyte S3 for Neuroscience

Sartorius

Nov 12, 2019

IncuCyte S3 Live-Cell Analysis System for Neuroscience: enables real-time automated measurements of the dynamic changes...

Webinar recording: Analysis of extracellular vesicles by AMNIS imaging flow cytometer

Luminex

Nov 4, 2019

Although conventional flow cytometry is limited to measure small particles down to approximately 300 nm – 500 nm, an...

Targeted mitochondrial DNA extraction and enrichment using the SageHLS

Sage Science

Oct 31, 2019

Sage Science introduced a novel approach for enriching mitochondrial DNA for sequence analysis without PCR or gradient...

Oncolytic chimeric orthopoxvirus causes regression of pancreatic cancer at a single low dose

Spectral Instruments Imaging

Oct 24, 2019

Pancreatic ductal adenocarcinoma (PDAC) has been increasing by 0.5% per year in the United States. This study describes...

Nov 14, 2019

New code dedicated to esophageal procedures with Confocal Laser Endomicroscopy

Mauna Kea Technologies

Oct 21, 2019

Announcement of the creation of a new specific procedural code to be added to the Common Classification of Medical...

VisualSonics AutoLV

VisualSonics FujiFilm

Sep 27, 2019

VisualSonics AutoLV allow functional and anatomical analysis of the left ventricle in one click using the power of...

New study resolves helicase dynamics and interactions during DNA replication using C-Trap

LUMICKS

Aug 30, 2019

Researchers from Rockefeller University used a C-Trap optical tweezers – fluorescence microscopy system to observe the...

Nov 14, 2019

Low-dose maging in a new preclinical total-body PET/CT scanner

Bruker Biospin

Aug 28, 2019

Ionizing radiation constitutes a health risk to imaging scientists and study animals. Both PET and CT produce ionizing...

Show all topics (10)

Tetraspanin Tspan9 regulates platelet collagen receptor diffusion and activation

Mar 2, 2017

Here we have characterized gene-trap mice lacking Tspan9. The mice were viable with normal platelet numbers and size. Tspan9-deficient platelets were specifically defective in aggregation and secretion induced by the platelet collagen receptor GPVI, despite normal surface GPVI expression levels. A GPVI activation defect was suggested by partially impaired GPVI-induced protein tyrosine phosphorylation. In mechanistic experiments, Tspan9 and GPVI co-immunoprecipitated and co-localised, but super-resolution imaging revealed no defects in collagen-induced GPVI clustering on Tspan9-deficient platelets. However, single particle tracking using total internal reflection fluorescence microscopy showed that GPVI lateral diffusion was reduced by approximately 50% in the absence of Tspan9. Therefore, Tspan9 plays a fine-tuning role in platelet activation by regulating GPVI membrane dynamics. 

Read more

Scientific paper

Related technologies: Cell interaction studies

Get more info

Riccardo Pasculli

Head of application support

Riccardo

Pasculli

+420 731 127 717

Send Message

Brand profile

Fluxion Biosciences

With BioFlux System for live cell analysis under shear flow and IsoFlux System for circulating tumor cell analysis, Fluxion Biosciences turn power of benchtop cellular analysis with advanced tools to automate complex assays.

Related products

Core control system, integrated to any inverted microscope to introduce flow to your research

show detail

System that offers a fully-integrated solution for automated, high throughput shear flow assays

show detail

We supply and support Life-Science Technologies in the territory of Central and Eastern Europe.

Czech Republic

Slovakia

Hungary

Poland

Croatia

Slovenia

Serbia

Romania

Bulgaria

Latvia

Lithuania

Estonia

Russia

Ukraine

Belarus

Turkey