Accelerate to discover

Back to filter

Related topics

The Role of Micro-CT in Imaging Breast Cancer Specimens

Bruker Biospin

Jun 17, 2020

The goal of breast cancer surgery is to remove all of the cancer with a minimum of normal tissue, but absence of full...

Bruker´s micro-CT used for some of the World’s First in vivo COVID-19 Imaging Experiments

Bruker Biospin

Jun 9, 2020

Bruker's BioSpin PreClinical Imaging Division reports the use of the Bruker SkyScan 1278 in vivo micro-CT system at the...

A mouse model of undifferentiated pleomorphic sarcoma mediated by adeno-Cre injection

Spectral Instruments Imaging

Jun 3, 2020

Soft tissue sarcomas pose a significant clinical challenge, with approximately 12,000 new diagnoses and an estimated...

Immunophenotyping Extracellular Vesicles using Amnis CellStream

Luminex

May 29, 2020

Attempts to analyze EVs using traditional PMT- based flow cytometers has been hampered by the limit of detection of...

Aug 13, 2020

Four-week individual caging of male ICR mice alters body composition without change in body mass

MEDIKORS

May 25, 2020

Could individual caging affect the physical composition of outbred mice? To investigate this, dual X-ray absorptiometry...

Detect structural variants at 1% allele fraction: Dive deeper into heterogeneous cancer samples

BioNano Genomics

May 22, 2020

To get a complete picture of highly rearranged cancer genomes in heterogeneous samples, use Bionano genome imaging...

Insulin receptor substrate 1 is a substrate of the Pim protein kinases

Spectral Instruments Imaging

May 18, 2020

The goal of these studies was to identify Pim substrate(s) that could help define the pathway regulated by these...

Aug 13, 2020

Implementation of Micro CT in CAD/CAM dentistry for image processing and soft computing

Bruker Biospin

May 4, 2020

Present radiology devices are playing an important role in clinical dentistry but their area of application islimited...

Show all topics (10)

Tetraspanin Tspan9 regulates platelet collagen receptor diffusion and activation

Mar 2, 2017

Here we have characterized gene-trap mice lacking Tspan9. The mice were viable with normal platelet numbers and size. Tspan9-deficient platelets were specifically defective in aggregation and secretion induced by the platelet collagen receptor GPVI, despite normal surface GPVI expression levels. A GPVI activation defect was suggested by partially impaired GPVI-induced protein tyrosine phosphorylation. In mechanistic experiments, Tspan9 and GPVI co-immunoprecipitated and co-localised, but super-resolution imaging revealed no defects in collagen-induced GPVI clustering on Tspan9-deficient platelets. However, single particle tracking using total internal reflection fluorescence microscopy showed that GPVI lateral diffusion was reduced by approximately 50% in the absence of Tspan9. Therefore, Tspan9 plays a fine-tuning role in platelet activation by regulating GPVI membrane dynamics. 

Read more

Scientific paper

Related technologies: Cell interaction studies

Get more info

Riccardo Pasculli

Head of application support

Riccardo

Pasculli

+420 731 127 717

Send Message

Brand profile

Fluxion Biosciences

With BioFlux System for live cell analysis under shear flow and IsoFlux System for circulating tumor cell analysis, Fluxion Biosciences turn power of benchtop cellular analysis with advanced tools to automate complex assays.

Related products

System that offers a fully-integrated solution for automated, high throughput shear flow assays

show detail

Core control system, integrated to any inverted microscope to introduce flow to your research

show detail

We supply and support Life-Science Technologies in the territory of Central and Eastern Europe.

Czech Republic

Slovakia

Hungary

Poland

Croatia

Slovenia

Serbia

Romania

Bulgaria

Latvia

Lithuania

Estonia

Russia

Ukraine

Belarus

Turkey