Products

The xCELLigence RTCA DP system is an easy to use platform with intuitive software and a variety of online tutorials for beginners and experience users. It is great tool for our cell therapies development, our laboratory obtained exciting results for cytotoxicity assays using adherent and suspension cells.

 

Dr Mirabela Cristea

Center for gene and cellular therapies in the treatment of cancer (OncoGen), Timisoara, Romania 

"xCELLigence system helped my research in performing real-time evaluation of the toxicological profile for several types of innovative drugs that were tested on both primary cells and standard cell lines. Additionally, this platform demonstrated high sensitivity of detection of intracellular signaling events for drugs targeting protein kinases-mediated cellular pathways."

Dr. Monica Neagu

'Victor Babeș' National Institute of Pathology, Bucharest, Romania

XCelligence system represents very usefull and user friendly tool for monitoring of cell proliferation and migration under different treatment and conditions.

Dr. Falk Martin, Ph.D

Institute of Biophysics of the Czech Academy of Sciences

"xCELLigence system is helping my research with fast and reliable screening experiments on cells proliferation, migration and invasion under different cells growth conditions."

Dr. Joanna Kozak

Medical University of Lublin, Human Anatomy Department

"We purchased the system as we had a good experience with it in past – our group works in the field of nanomedicine. In experiments, various nanomaterials (carbon, magnetic particles) are modified by antitumor drugs and other molecules for specific targeting of tumor cells.
The the greatest benefit of the system is that the experiments are easy to set up, the data are obtained in a relatively short time without the need for more complicated sample manipulation. The method makes it possible not only to monitor the increasing number of cells, but also to evaluate the progress of this process - to elegantly determine the growth characteristics of the studied cells and to test the substances used. The process is completely independent of the human factor, thereby minimizing common experimental errors."

Prof. René Kizek

University of Veterinary and Pharmaceutical Sciences, Brno, Czech Republic

xCELLigence DP - Agilent technologies

The technology extended into most powerful cell migration tool

The RTCA DP Analyzer has three integrated stations for E-Plates 16 or CIM-Plates 16.It is located inside a tissue culture incubator. Each of the three 16-well plate holders can be used independently under the RTCA Software. The RTCA DP Analyzer can automatically select wells for measurement and continuously transfer measured impedance data to the computer. Cell Index values, derived from the measured impedances, are continuously displayed on the Software user interface.

The RTCA DP Instrument is composed of three main components: 

  • RTCA DP Analyzer
  • RTCA Control Unit
  • E-Plate 16 or CIM-Plates 16

RTCA DP Instrument Highlights: 

  • Highly flexible low throughput: Accommodates up to three E-Plates 16 or CIM-Plates 16 simultaneously
  • Flexibility: Independent operation of the three 16 well plates by up to three different users
  • Clear data presentation: 16-well graph shows individual Cell Index curves for all 16 wells
  • Broad range of applications for cellular assays and cell invasion migration assays

Show more

https://www.aceabio.com/products/rtca-dp/

Discover more

Cancer Immunotherapy Applications of xCELLigence Real-Time Cell Analysis (RTCA) Systems Use of the real time xCelligence system for purposes of medical microbiology xCELLigence cancer immunotherapy: NK cell-mediated cytolysis In vitro hypoxia studies using xCELLigence platform Real-time chemotaxis of macrophages Quantifying virus-mediated cytopathic effect with xCELLigence platform Introducing the xCELLigence Immunotherapy kit – B Cell killing assay Real-time monitoring of Human Skin-Derived Precursor (SKPs) cell differentiation Assessment of CAR T Cell killing capacity against solid tumors-Thursday, October 20, 2016, 5 pm CEST Cancer immunotherapy: Macrophage-mediated phagocytosis Monitoring in real time the formation and removal of biofilms from clinical related pathogens xCELLigence in personalized cancer medicine Investigating the hallmarks of cancer using xCELLigence system Monitoring the formation and removal of biofilms from clinically relevant pathogens in real-time Real-time determination of virus titers using cell electric impedance technology Label-free monitoring of T cell activation by the impedance-based system A novel high throughput assay for diagnosis by real-time monitoring of parasite motility Optimization of (CAR) T cell design guided by sensitive sssessment of B cell killing Cellular impedance measurement- novel method for in-vitro investigation of drug efficacy Cellular impedance measurement- response of OVCAR-3 cells to Cisplatin and hyperthermia Automated continuous monitoring of growth factor-mediated Endothelial cell migration ACEA webinar series: Using xCELLigence RTCA to study biofilms formation Protectome analysis: A new selective tool for bacterial vaccine discovery Kinase study of cytotoxicity voted paper of the year. ACEA Biosciences launch xCELLigence RTCA software Pro for immunotherapy applications New technique for dynamic monitoring of liquid tumor Cytotoxicity xCELLigence system: rapid and sensitive, ideal for infectious viral assays.
Riccardo Pasculli

Head of application support

Riccardo

Pasculli

+420 731 127 717

Send Message

Setup a demonstration
with our specialist

Request a demo

Related products

Instrument can be integrated with automated liquid handling platforms or a robotic plate handler from different vendors

show detail

Located inside a tissue culture incubator, it is capable of switching any one of the wells on the E-Plate 96 to the RTCA Analyzer for impedance measurement

show detail

Located inside a tissue culture incubator, it is capable of switching any one of the wells on any of six E-Plates to the RTCA Analyzer for impedance measurement

show detail

Located inside a tissue culture incubator, S16 continuously monitor live cell proliferation, morphology and viability with label free assays in a 16 well format.

show detail

Cardio Instrument is a high-resolution system for label-free-dual-mode monitoring of cardiomyocyte and cardiotoxicity testing

show detail

The new CardioECR system combines impedance and Multi Electrode Array (MEA) technology with a pacing function

show detail

The eSight system combines the label-free xCELLigence RTCA technology with live cell imaging in 3 colors (red, green, and blue), all inside your incubator

show detail

We supply and support Life-Science Technologies in the territory of Central and Eastern Europe.

Czech Republic

Slovakia

Hungary

Poland

Croatia

Slovenia

Serbia

Romania

Bulgaria

Latvia

Lithuania

Estonia

Russia

Ukraine

Belarus

Turkey